Your Trusted Partner in Power & Technology

Power & Distribution Transformers

High-Efficiency 11/0.415 kV & 33/11 kV Substation Transformer Solutions

Custom-designed 3-phase oil-immersed transformers manufactured strictly with Cold Rolled Grain Oriented (CRGO) silicon steel, delivering ultra-low losses, robust dielectric withstand, and decades of reliable power operation.

World-Class Transformer Engineering & Manufacturing

VOLTCORE Engineering Solutions manufactures robust 3-Phase Distribution and Power Transformers custom-engineered to client requirements and international standards including IEC, ANSI, BS, VDE, and BSTI.

Our transformers range in rating from 50 KVA to 5,000 KVA for 11/0.415 kV distribution networks and up to 18,000 KVA for 33/11 kV grid substations. As a consistent guarantee of the highest quality, our transformers are fabricated with high-permeability Cold Rolled Grain Oriented (CRGO) silicon steel laminations with step-lap mitered joints for minimal hysteresis and eddy-current core loss.

Our engineering team is closely affiliated with international professional bodies such as IEEE and ASME, continuously incorporating state-of-the-art power engineering developments. Quality control is executed at every single stage of production, and all units undergo exhaustive routine and type testing in our well-equipped high-voltage testing laboratory in compliance with IEC-76, BDS-1081, ANSI, and BSTI standards.

Power & Distribution Transformers
Global Engineering Affiliations & Research Compliance:
IEEE (Institute of Electrical and Electronics Engineers) ASME (American Society of Mechanical Engineers) BSTI / BDS-1081 Certified IEC 60076 Conformance

Voltcore Official Quality Policy & Assurance Pillars

01

Reliable Power

The Reliable Power: High dielectric stability, heavy-duty thermal endurance, and vacuum-treated mineral transformer oil.

02

Customer Priority

Customer-Centric Engineering: Fully tailored impedance, tapping ranges, dual LV/HV bushings, and custom enclosure dimensions.

03

In-Time Delivery

24/7 In-Time Delivery & Support: Emergency breakdown dispatch, testing, commissioning, and preventive maintenance contracts.

04

Continuous CRGO Lab Testing

Continuous CRGO Optimization: Precision step-lap core stacking, low contact erosion, and low-loss electrolytic copper windings.

Engineered Transformer Solutions: 11kV & 33kV

Whether stepping down 11kV utility feeds to 415V for industrial and commercial factories, or stepping down 33kV primary transmission lines to 11kV for utility substations, Voltcore delivers turnkey custom-engineered transformers.

Distribution Class
11 / 0.415 kV

11 / 0.415 kV 3-Phase Distribution Transformers

Primary 11,000V (11kV) • Secondary 415V / 440V
Capacity Range: Standard Ratings: 50 KVA up to 3,000 KVA (and up to 5,000 KVA on request)

Engineered for commercial complexes, industrial plants, RMG factories, residential developments, and rural electrification networks. Built with corrugated cooling fins or pressed sheet radiators for superior natural oil circulation (ONAN).

Standard Design Features:

  • Off-Circuit Tap Switch: ±2.5%, ±5% or ±2×2.5% to -7.5%
  • Core: High-grade CRGO M4 / M5 prime silicon steel
  • Windings: 99.9% electrolytic high-conductivity copper
  • Tank: Hermetically sealed or conservator tank with silica gel breather
  • Bushings: High-voltage porcelain DIN bushings with arc horns
  • Protection: Oil level indicator, thermometer pocket, pressure relief device
Power Class
33 / 11 kV

33 / 11 kV 3-Phase Power Transformers

Primary 33,000V (33kV) • Secondary 11,000V (11kV)
Capacity Range: Standard Ratings: 1,000 KVA up to 18,000 KVA (18 MVA)

Heavy-duty substation power transformers engineered for utility grid step-down, industrial economic zones (EPZ), high-demand manufacturing plants, and utility-scale solar power grid interconnects. Designed to withstand severe lightning impulses, switching over-voltages, and system short-circuit stresses.

Standard Design Features:

  • Tappings: Off-Circuit Tap Changer (OCTC) or On-Load Tap Changer (OLTC)
  • Cooling: ONAN (Oil Natural Air Natural) / ONAF (Oil Natural Air Forced)
  • Core: Step-lap CRGO with high stacking factor and low magnetizing current
  • Protection: Buchholz double-float gas relay, magnetic oil gauge (MOG), WTI & OTI with alarm/trip contacts
  • Impulse Withstand: Up to 170 kV BIL peak impulse insulation level
  • Testing: Rigorous routine, temperature rise, and impulse testing according to IEC 60076

Transformer Design Parameters & Construction Standards

Applicable Standards
IEC 76, BDS-1081, ANSI, VDE, BS, AEC, BSTI
System Frequency
50 Hz standard (60 Hz available on request)
Ratings Capacity
50 KVA to 5,000 KVA (Distribution) | 1,000 KVA to 18,000 KVA (33/11kV Power)
Primary Voltages
11 kV or 33 kV (Values above 24 kV up to 36 kV; Double high voltages 15–20 kV available)
Tapping Facilities
2.5%; ±5% or ±2×2.5% to -7.5% (Off-Circuit or On-Load Tap Changer)
Secondary Voltages
415V to 440V (Double low voltages with 7 LV bushings with full rating on both voltages or 75% on load)
Core Magnetic Material
Prime Cold Rolled Grain Oriented (CRGO) silicon steel laminations
Cooling Medium
ONAN (Oil Natural Air Natural) / ONAF (Oil Natural Air Forced)
Insulation Class & Vector Group
Class A (105°C) uniform insulation with premium Kraft paper and pressboard spacers • Dyn11 (Standard 11kV Distribution) | YNd11 or Dyn11 (33kV Power)

Electrical Specifications for Transformers

Full technical data table covering losses, efficiency at unity power factor, oil weight, total weight, overall dimensions, and impedance voltage.

Table 1: 11000/415 Volt, 3-Phase Distribution Transformers 17 Standard Ratings
System Frequency: 50Hz • Cooling: ONAN • Core: CRGO Silicon Steel
Sl. Capacity
(kVA)
No Load
Loss (W)
Load Loss
at 75°C (W)
Efficiency @
Unity PF (%)
Oil Wt
(kg)
Total Wt
(kg)
Length
(cm)
Width
(cm)
Height
(cm)
Impedance
(%)
01 50 KVA 150 925 98.00% 140 580 94 58 118 4.0%
02 100 KVA 245 1700 98.42% 180 650 100 63 132 4.0%
03 150 KVA 320 2412 98.60% 220 900 105 88 145 4.0%
04 200 KVA 435 2820 98.79% 230 975 112 93 150 4.0%
05 250 KVA 520 3265 98.81% 270 1100 113 95 158 4.0%
06 315 KVA 580 4500 98.89% 350 1250 120 97 160 4.0%
07 400 KVA 722 5490 98.95% 390 1450 123 98 162 4.0%
08 500 KVA 865 6275 99.00% 425 1725 124 102 165 4.0%
09 630 KVA 920 7740 99.05% 500 1970 136 103 170 4.5%
10 750 KVA 1150 8850 99.06% 625 2250 155 112 185 5.0%
11 800 KVA 1300 9800 99.06% 650 2575 170 113 200 5.0%
12 1000 KVA 1650 11600 99.08% 800 2850 185 115 215 5.0%
13 1250 KVA 1820 12300 99.10% 1000 3725 190 116 225 5.0%
14 1600 KVA 2200 14275 99.12% 1200 4300 200 120 230 6.0%
15 2000 KVA 2650 16470 99.15% 1450 4750 210 135 250 6.0%
16 2500 KVA 3140 19700 99.17% 1800 5600 220 150 285 6.5%
17 3000 KVA 3420 22860 99.19% 2050 6350 230 170 300 6.5%

* Note on Specifications: All transformer specifications, loss levels, weights, and overall dimensions conform to official IEC-76 and BDS-1081 standards. Custom impedance voltages, special primary/secondary voltage combinations, and customized dimensional footprints can be engineered strictly as per customer requirements upon technical review.

Complete 33/11kV & 11/0.415kV Substation System Integration

In addition to manufacturing world-class transformers, VOLTCORE provides complete HT Switchgear (VCB/LBS), LT Switchgear, Power Factor Improvement (PFI) Plants, Lightning Protection, and Substation Earthing systems.